| Management number | 233883094 | Release Date | 2026/06/27 | List Price | US$99.67 | Model Number | 233883094 | ||
|---|---|---|---|---|---|---|---|---|---|
| Category | |||||||||
Battery ChargersBAC2405 Auto Diesel Generator Battery Charger 5A 24V Module Electric Short Circuit Protection Genset PartDescription:1. SUMMARYFit with up-to-date power supply device, float charger BAC2405 is specially designed for meet the charging characteristics of the lead-acid engine starter batteries and can be used for long-term float charging of 24V lead-acid batteries .2 .PERFORMANCE AND CHARACTERISTICS Switch power supply structure, wide input alternating voltage range, small size, light weight, high efficiency rate;Automatic two-stage charging process (first constant current, then constant voltage) carried out according to storage battery charging characteristics to prevent overcharging and significantly prolong battery lifetime;Built-in current protective circuit for short-circuit protection and reverse connection protection;Charging voltage and current can be adjusted via potentiometer on the spot;Suitable for 24V storage battery and the rated current is 5A;LED display: Power indication and charging indication.Charging is performed according to the battery charging characteristics using two-stage method. Charging type is 'constant current type' which means that when the battery terminal voltage falls below the pre-set value, charging current will be constant; when the battery terminal voltage exceeds the pre-set value, charging current will decrease with the rising of terminal voltage until the pre-set current value is reached; then Chargers automatically to float mode. As soon as charging current value falls below 0.5A and the constant voltage value is reached, the battery is basically charged (charging indicator will extinguish). After that charging current will only neutralize the battery self discharge. Even long-term charging cannot harm the battery, as charger can keep the battery fully charged and so guarantee long lifetime of the battery.4. SPECIFICATION6. VOLTAGE/CURRENT REGULATION6.1 VOLTAGE REGULATIONIf adjust voltage on-site, battery need to be disconnected with battery charger, and then adjust the voltage potentiometer (VOLT) to the appropriate value while measuring the charger output voltage.6.2 CURRENT REGULATIONAfter connecting output port to the storage battery, measuring charging current under 25.0V charging voltage, and then adjust the current potentiometer (AMP) to the appropriate value. Current also can be estimated according to the scale of the current potentiometer.Connect terminals L and N to alternating voltage 220V, using BVR 1mm2 multi-strand copper line.Connect B+ and B- to battery positive and negative using multi-strand BVR1.5mm2 copper wires.POWER: power supply indicator, illuminated when the charger is operating normally.CHARGING: charging indicator, illuminated when charging current exceeds 0.5A while extinguished when charging current has fallen below 0.5A.VOLT: charging voltage regulator-potentiometerAMP: charging current regulator-potentiometerFUSE: output fuse; rated current: 10A. If connected in the wrong way, the fuse will be burnt out and then voltage free. In this case connect cables correctly, replace the fuse and the system will continue to operate normally.7.2 BAC2405 TROUBLESHOOTING7.2.1 FAULT DIAGNOSISOutput terminal of battery charger short circuit or battery reverse connection may blow the charger output fuse. In that case, after connecting AC power supply, charger green LED lights up but output terminal without voltage outputting, and then remove the output fuse tube to visually observe whether fuse is blown or not, if condition permit, multimeter can be used to measure the fuse status.a) If output terminal 10A fuse is blown, users only need to change the same capacity fuse.b) If output fuse isn't blown or battery without outputting after changing the fuse, battery needs to depot repair.c) Fuse burn emergency method: using conductive metal wire short connected burnt fuse, and then change the fuse later.7.2.2 PROCEDURES OF CHANGING FUSEa) Press hard on the slotted screwdriver, screw counter-clockwise and then take out the fuse.( improper operation or over tightening may damage the block)b) Put a fuse into the block, press the slotted screwdriver and screw clockwise.==========Hign-concerned Chemical : NoneModel Number : BAC2405Key words: : BAC2405Application: : for diesel generator
| ASIN | B0FLKD4YL9 |
|---|---|
| Brand | KDNHVRQY |
| Color | One Color |
| Manufacturer | KDNHVRQY |
| Model Number | KDNHVRQY |
| Input Voltage | 1 Kilovolts |
| Mfr Part Number | KDNHVRQY |
| Specification Met | UL |
| Item Dimensions D x W x H | 0.39"D x 0.39"W x 0.39"H |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form